Search
Now showing items 1-4 of 4
Reduction of Measurement Error in Microwave Reflectometers by Minimum Sensitivity Calibration
(1993-07-08)
Explicit formulas for the sensitivities of the error corrected reflection coefficient (RC) with respect to the RCs of the calibrating elements, and the invariance of their sum are presented. Under the condition that the ...
Modelling Electro-Optical Interaction in MESFETs
(1993-07-01)
A modelling procedure is presented for MESFETs with both electrical and optical inputs. First a physical model is introduced for the illuminated MESFET. The actual circuit model with electrical and optical variables is ...
Harmonic-Balance Analysis of Optically Injection Locked Microwave FET Oscillators
(1993-09-06)
The paper discusses the application of harmonic-balance (HB) techniques to the analysis of optical injection locking of microwave FET oscillators. HB methods are first extended to cover the case of a circuit excited by a ...