Reduction of Measurement Error in Microwave Reflectometers by Minimum Sensitivity Calibration

Megtekintés/ Megnyitás
Metaadat
Teljes megjelenítés
Link a dokumentumra való hivatkozáshoz:
Gyűjtemény
Absztrakt
Explicit formulas for the sensitivities of the error corrected reflection coefficient (RC) with respect to the RCs of the calibrating elements, and the invariance of their sum are presented. Under the condition that the sum of the sensitivities is constant, the sum of the absolute values of the sensitivities achieves a global minimum if the measured RC coincides with the altitude centre of the triangle formed by the RCs of the calibrating elements, or with one of the RCs of the calibrating elements. In the examples, 8 dB error reduction was found.- Cím és alcím
- Reduction of Measurement Error in Microwave Reflectometers by Minimum Sensitivity Calibration
- Szerző
- Ladvánszky, János
- Hilt, Attila
- Csonka, István
- Megjelenés ideje
- 1993-07-08
- Hozzáférés szintje
- Címtáras bejelentkezéshez kötött BME-felhasználók
- Szerzői jog tulajdonosa
- IEE
- Nyelv
- en
- Tárgyszó
- measurement error, microwave reflectometer, calibration, sensitivity
- Változat
- Post print
- Egyéb azonosítók
- DOI: 10.1049/EL:19930871
- MTMT: 1962787
- Scopus: 0027912097
- Web of Science: A1993LW31700048
- A cikket/könyvrészletet tartalmazó dokumentum címe
- Electronics Letters
- A forrás folyóirat éve
- 1993
- A forrás folyóirat évfolyama
- Vol.29
- A forrás folyóirat száma
- No.14
- ISSN, e-ISSN
- ISSN: 0013-5194
- eISSN: 1350-911X
- Dokumentumtípus
- Folyóiratcikk
- Műfaj
- Tudományos cikk
- Tudományterület
- Műszaki tudományok
- Tudományág
- Villamosmérnöki tudományok
- Kar
- Villamosmérnöki és Informatikai Kar