Reduction of Measurement Error in Microwave Reflectometers by Minimum Sensitivity Calibration

View/ Open
Metadata
Show full item record
Link to refer to this document:
Collections
Abstract
Explicit formulas for the sensitivities of the error corrected reflection coefficient (RC) with respect to the RCs of the calibrating elements, and the invariance of their sum are presented. Under the condition that the sum of the sensitivities is constant, the sum of the absolute values of the sensitivities achieves a global minimum if the measured RC coincides with the altitude centre of the triangle formed by the RCs of the calibrating elements, or with one of the RCs of the calibrating elements. In the examples, 8 dB error reduction was found.- Title
- Reduction of Measurement Error in Microwave Reflectometers by Minimum Sensitivity Calibration
- Author
- Ladvánszky, János
- Hilt, Attila
- Csonka, István
- Date of issue
- 1993-07-08
- Access level
- Címtáras bejelentkezéshez kötött BME-felhasználók
- Copyright owner
- IEE
- Language
- en
- Subject
- measurement error, microwave reflectometer, calibration, sensitivity
- Version
- Post print
- Identifiers
- DOI: 10.1049/EL:19930871
- MTMT: 1962787
- Scopus: 0027912097
- Web of Science: A1993LW31700048
- Title of the container document
- Electronics Letters
- Year of container document
- 1993
- Volume of container document
- Vol.29
- Number of container document
- No.14
- ISSN, e-ISSN
- ISSN: 0013-5194
- eISSN: 1350-911X
- Document type
- Folyóiratcikk
- Document genre
- Tudományos cikk
- Subject area
- Műszaki tudományok
- Field
- Villamosmérnöki tudományok
- Faculty
- Villamosmérnöki és Informatikai Kar